I am having a hard time finding replacement glass for the rear slide out sliding window. It is double-paned, measuring approximately 25"H x 48" L.
Half of the outlets are not powered, and the green light on the affected inverter is not lit. The Vegatouch indicates that inverter number two is not powered or charging. Shore power is connected and both lines are confirmed to be outputting 120V. The breaker/thermal on the Magna Inverter chassis is not popped. Questions include whether AC flow works if the inverter/charger is faulty, if the AC power doesn’t flow through during an internal failure of the Magna, how to test if the inverter is faulty, and whether there are GFCIs in the rig.
The SW6DE water heater provides electric and propane heating. The propane side works, and the AC side has been tested for a stuck toggle switch, continuity, and resistance with no issues found. The heating element also shows continuity. The AC side does not produce hot water after 2 hours of operation. What steps should be taken next to diagnose the AC heating issue?
I need a replacement converter/inverter for my 5th wheel. Have 2 12v batteries hooked up in parallel. I am a volunteer park host for Fresno county, California, and am 'permantly' located so use 12v system for the 22v lights etc only. And need to keep batteries charged.